OVERVIEW:

  • Log and trend measurements to pinpoint intermittent faults
  • Transmit results wirelessly via Fluke Connect® Measurements app
  • Create and send reports right from the field
  • Stay safely away from the arc flash zone through Bluetooth connectivity to Apple and Android devices


Features:

  • Connect your meter to your smartphone with Fluke Connect Measurements
  • Read measurements on your phone at a safe distance, wearing less PPE while your meter takes all the risks
  • Record results directly to your phone and the Cloud
  • Capture intermittent faults while performing other tasks using the logging capabilities of the Fluke 376 FC
  • Create and share reports from the field via email, or converse in real-time with ShareLive™ video calls
  • iFlex flexible current probe expands the measurement range to 2500 A ac; provides access to large conductors in tight spaces (included)
  • TPAK magnetic hanging strap (included)
  • Integrated VFD low pass filter for accurate motor drive measurements
  • Proprietary inrush measurement technology to filter out noise and capture motor starting current exactly as the circuit protection sees it
  • CAT IV 600 V, CAT III 1000 V safety rating
  • Soft carrying case
  • Measurement Capability
  • 1000 A ac and dc current measurement
  • 2500 A ac current measurement with iFlex flexible current probe
  • 1000 V ac and dc voltage measurement
  • True-RMS voltage and current for accurate measurements on non-linear signals
  • Frequency measurement to 500 Hz with body jaw and iFlex
  • Resistance measurement to 60 kΩ with continuity detection
  • Min, max, average, and inrush recording to capture variations automatically
  • 500 mV dc measurement range to interface with other accessories
  • 1000 μF capacitance measurement

Document:

FLUKE 376 FC Clamp Meter

Product Details
Product Name FLUKE 376 FC True-rms AC/DC Clamp Meter with iFlex
Price Rs. 150,000/-
POWER
AC Voltage Range 374 and 375 600.0 V 376 1000 V Accuracy 1.5% ± 5 digits (20 – 500 Hz) Resolution 374 and 375 0.1 V 376 0.1 V (≤ 600.0 V) 1 V (≤ 1000 V)
DC Voltage Range 374 and 375 600.0 V 376 1000 V Resolution 374 and 375 0.1 V 376 0.1 V (≤ 600.0 V) 1 V (≤ 1000 V) Accuracy 1% ± 5 digits
Summary
Crest factor (50/60 Hz) 3 @ 500 A (375 and 376 only) 2.5 @ 600 A 1.42 @1000 A (376 only) Add 2% for C.F. > 2
Crest Factor (AC Current) (50/60Hz) 3.0 at 1100 A (375 and 376 only) 2.5 at 1400 A 1.42 at 2500 A Add 2% for C.F. > 2
EMC Standard EN 61326-1:2006
mV dc Range 375 and 376 500.0 mV Resolution 0.1 mV Accuracy 1% ± 5 digits
Resolution (AC Current) 374 and 375 0.1 A (≤ 600 A) 1 A (≤ 2500 A) 376 0.1 A (≤ 999.9 A) 1 A (≤ 2500 A)
Temperature Coefficients Add 0.1 x specified accuracy for each degree C above 28°C or below 18°C
Capacitance Range 1000 μF Resolution 0.1 μF (≤ 100 μF) 1 μ F (≤ 1000 μF) Accuracy 1% ± 4 digits
DC Current Range 374 and 375 600.0 A 376 999.9 A Resolution 0.1 A Accuracy 2% ± 5 digits
Resistance Range 374 6000 Ω 375 and 376 60 kΩ Resolution 374 0.1 Ω (≤ 600 Ω) 1 Ω (≤ 6000 Ω) 375 and 376 0.1 Ω (≤ 600 Ω) 1 Ω (≤ 6000 Ω) 10 Ω (≤ 60 kΩ) Accuracy 1% ± 5 digits
Accuracy 2% ± 5 digits (10-100 Hz) 2.5% ± 5 digits (100-500 Hz)
Resolution 374 and 375 0.1 A (≤ 600 A) 1 A (≤ 2500 A)
Range 374 and 375 376 600.0 A 999.9 A
Size (L x W x H) 246 mm x 83 m x 43 mm
HARDWARE FEATURES
Weight 388 g
TECHNICAL SPECIFICATION
Accuracy (AC Current) 3% ±5 digits (5 – 500 Hz)
Operating Altitude 3000 meters
Operating Humidity Non condensing (< 10 –°C) ≤ 90% RH (at 10°C – 30°C) ≤ 75% RH (at 30°C – 40°C) ≤ 45% RH (at 40°C – 50°C)
Operating Temperature 10°C – +50°C
Range (AC Current) 2500 A
Safety Compliance CAN/CSA-C22.2 No. 61010-1-04 ANSI/UL 61010-1:2004 ANSI/ISA-61010-1 (82.02.01):2004 EN/IEC 61010-1:2001 to 1000V Measurement Category (CAT) III 600V Measurement Category (CAT) IV Pollution Degree 2 EN/IEC 61010-2-032:2002 EN/IEC 61010-031:2002+A1:2008
Storage Altitude 12,000 meters
Storage temperature -40°C – +60°C
General Specification
Frequency via Flexible Current Probe Range 375 and 376 5.0 - 500.0 Hz Resolution 0.1 Hz Accuracy 0.5% ± 5 digits Trigger Level 5 – 20 Hz, ≥ 25 A 20 – 100 Hz, ≥ 20 A 100 – 500 Hz, ≥ 25 A
Frequency via Jaw Range 375 and 376 5.0 - 500.0 Hz Resolution 0.1 Hz Accuracy 0.5% ± 5 digits Trigger Level 5 – 10 Hz, ≥10 A 10 – 100 Hz, ≥5 A 100 – 500 Hz, ≥10 A
Batteries & Runtime
Battery type 2 AA, NEDA 15A, IEC LR6