ABB CM-PVS.41S Under/Over Voltage, Phase Sequence / Phase Failure

ABB CM-PVS.41S Under/Over Voltage, Phase Sequence / Phase Failure price in Paksitan
ABB CM-PVS.41S Under/Over Voltage, Phase Sequence / Phase Failure
  • Stock Availability: In Stock
  • Model: WABB-317
Product Views: 6986
Rs. 35,000/-

OVERVIEW:

The CM-PVS.41S relay is from the CM three-phase monitors range. This relay operates with a rated control supply voltage / three-phase measuring voltage of 300-500 V AC and has a 2 c/o output with contacts rated at 250 V / 4 A. The CM-PVS.41S monitors the phase parameters over/undervoltage and phase failure. The corresponding threshold values are adjustable. Phase sequence monitoring as well as an ON or OFF tripping delay are selectable. The tripping delay is adjustable over a range of instantaneous to 30 s (0, 0.1-30 s). A sealable transparent cover for protection against unauthorized changes is available as accessory. The device offers screw connection technology with double-chamber cage connection terminals.

Document:


Explore w11stop.com find out latest ABB products & other electronic components at discounted price in Pakistan with free cash on delivery service across Pakistan. We are dealing ABB in Pakistan.

Product Details
Product Name ABB CM-PVS.41S Under/Over Voltage, Phase Sequence / Phase Failure
Price Rs. 35,000/-
Summary
Function Phase failure detection | Phase sequence monitoring | Over- and undervoltage monitoring
Measuring range (L-L) 300 ... 500 V AC
Pollution Degree 3
HARDWARE FEATURES
Degree of protection Housing IP50 | Terminals IP20
Supply Voltage Rated Control (Us) : (L-L) 300 ... 500 V AC
Terminal Type Screw Terminals
TECHNICAL SPECIFICATION
Ambient Air Temperature Operation -25 ... +60 °C | Storage -40 ... +85 °C
Impulse Withstand Voltage Rated (Uimp) : Input Circuit 6 kV | Output Circuit 4 kV
Rated Frequency Supply Circuit 50/60 Hz
Rated Insulation Voltage (Ui) : Input Circuit / Output Circuit 600 V | Output Circuit 1 / Output Circuit 2 300 V
Rated Operational Current AC-12 (Ie) : (230 V) 4 A | AC-15 (Ie) : (230 V) 3 A | DC-12 (Ie) : (24 V) 4 A | DC-13 (Ie) : (24 V) 2 A |
General Specification
Electrical Durability AC-12 100000 cycle
Mechanical Durability 30000000 cycle
Output 2 c/o (SPDT) contacts
Standard CAN/CSA C22.2 No.14 | EN 50581 | IEC/EN 60255-27 | IEC/EN 61000-6-2 | IEC/EN 61000-6-3 | UL 508
Tightening Torque 0.6 ... 0.8 N·m
Time Range 200 ms start-up delay | 0 s or 0.1 ... 30 s tripping delay (ON or OFF)
Type Phase Sequence / Phase Failure