Hanna HI-8410 Panel Mounted Dissolved Oxygen Controller

Hanna HI-8410 Panel Mounted Dissolved Oxygen Controller price in Paksitan
Inquiry
Hanna HI-8410 Panel Mounted Dissolved Oxygen Controller
  • Stock Availability: Inquiry
  • Model: HANS-28
Product Views: 5405
Rs. 350,000/-

OVERVIEW:

The HI8410 is a panel mounted dissolved oxygen controller that is used to maintain and monitor the concentration of DO in a wide range of industrial process applications. The HI8410 uses a Galvanic probe that typically requires less maintenance than a Polarographic style making it ideal for long term monitoring.

The set point for controlling the activation of a relay is adjusted manually by the user. An alarm relay is also manually adjustable and is based upon a tolerance from the programmed setpoint. This controller features single set point calibration in zero oxygen solution.
The dosage mode: automatic, continuous ON or OFF and over dosage control by setting the overtime dosage trimmer. If the dosing relay remains continuously activated for more than the selected dosing time, the alarm relay is activated, the alarm LED will start blinking and the dosing relay will be deactivated. A jumper located on the controller’s rear panel can disable the “over time dosage” function.

Fail Safe Alarm Syste:

Hanna’s exclusive Fail Safe Alarm System protects against problems caused by power supply failure or signal interruption, which are typical risks in industrial environments. An alarm condition is indicated by a red LED, located directly on the front panel of the controller.

Automatic Temperature Compensation:

The Dissolved Oxygen readings are automatically compensated for the temperature effects on the oxygen solubility and membrane
permeability.

Salinty Compensation:

The salinity compensation feature allows the determination of Dissolved Oxygen even in salty waters.

Simple to Use:

The instruments are designed with a standard DIN panel mount with membrane keypads and large LCD with backlight on the front, and provide a series of auto-diagnostic functions.

Analog Output:

To enhance troubleshooting and the ability to record data while monitoring, simply attach a recording device to the instrument’s 4 to 20 mA
output contacts, conveniently located on the front panel, to obtain a copy of the results on demand.

Diagnostic Tests:

The HI 8410 controllers are designed with built-in diagnostic functions to enable the user to check and troubleshoot the instrument. The checks performed are through the front panel keys and can be used to isolate the cause of malfunction.

Document:

Product Details
Product Name Hanna HI-8410 Panel Mounted Dissolved Oxygen Controller
Price Rs. 265,000/-
Summary
Calibration Manual, one point, in saturated air
Resolution 0.1 mg/L or 1% ( O2) / 0.1 °C
HARDWARE FEATURES
Backlight Continuous ON
Enclosure Black anodized aluminum body; front-panel with flame retardant ABS; transparent splash-proof front cover
TECHNICAL SPECIFICATION
Temperature Compensation Automatic, from -5 to 50 °C (23 to 122 °F)
General Specification
Accuracy ±1% of reading ( O2) / ±0.2 °C
Alarm Range 1.0 to 5.0 mg/L (ppm) O2
Dosing Control OFF/AUTO/ON with selection switch
Hysteresis Range 0.1 to 1.0 mg/L (ppm) O2
Input High impedance 1012 Ohm; Reference annd Matching pin inputs are available; 4-20 mA
Panel Cutout 141 x 69 mm
Range 0.0 to 50.0 mg/L (ppm) O2 0 to 600 % O2 -5.0 to 50.0 °C
Recorder Output 0 to 20 mA or 4 to 20 mA (isolated)
Salinity Compensation 0 to 51 g/L (resolution 1 g/L)Probe
Setpoint Range 1 to 600 % O2;0.1 to 50.0 mg/L (ppm) O2
Weight 1 kg
Power Supply 115 Vac ±10% or 230 Vac ±10%; 50/60 Hz
Dimension -10 to 50°C