Lutron PM-1064SD Particle Counter
Rs. 113,000/-
Lutron PM-1064SD Particle Counter price in Pakistan is
Rs. 113,000/-
. W11stop.com has wide range of Industrial Meters with cash on delivery service in Karachi, Lahore, Multan, Peshawar and many other cities.FEATURES:
- Monitoring air pollutant sources from dust, petrochemical industry, steel-making plant,
- the thermal power plant, restaurant, smoke, burning plants, driving automobiles.
- The meter is a real-time air quality monitor instrument used to monitor the concentration
- of PM2.5, humidity, and temperature in the indoor environment
- PM2.5 : 0 to 250 µ g/m^3, Humidity : 5 to 95 %RH, Temperature : 0 to 50 , / . ℃℃℉
- CO2 : 0 to 10,000 ppm, Barometer : 10 to 1100 hPa, mmHg, inHg.
- PM2.5 time-weighted average reading.
- Data hold, Record(Max, Min)
- Alarm setting with the beeper sound output.
- Health index ( 0-9 ) detection and alarm.
- Built-in clock and Calendar, real-time data record with SD memory card, sampling time can
- be set from 1 second to 3600 seconds. Just slot the SD card into the computer, all the
- measured values with the time information ( year, month, date, hour, minute, second ) can
- be downloaded to the Excel directly, then the user can make the further data analysis by
- themselves.
- The manual data record is available, can set the different position(location) No.( 1 to 99 ).
- SD card capacity : 1GB to 32GB.
- Dot-matrix LCD display.
- Power by UM3/AA(1.5V) X 6 batteries or DC 9V adapter
- RS232/USB PC computer interface
Document:
Product Details | |
Product Name | Lutron PM-1064SD Particle Counter |
Price | Rs. 113,000/- |
Display Specification | |
Display | LCD Size: 2.18 X 2.87" (55.4 X 72.9 mm). Dot matrix backlit LCD (128 X 240 pixels). |
Over Range | * LCD display show " OL ".. * The data save into the Micro SD card will show " 999 " (overleap the decimal point). |
Summary | |
Resolution | 1 µ g/m^3 |
Sampling Time | Approx. 1 second. |
Power Consumption | DC 135 mA approximately. Backlight ON approximately DC 150 mA |
TECHNICAL SPECIFICATION | |
Operating Humidity | Less than 80% R.H.. |
General Specification | |
Accuracy | ± ( 10 % reading ± 20µ g/m^3 ) |
Circuit | Custom single-chip microprocessor LSI circuit |
Measurement | PM2.5 : 0 to 250 µ g/m^3, Humidity : 5 to 95 %RH, CO2 : 0 to 10,000 ppm, Barometer : 10 to 1100 hPa, Temperature : 0 to 50 , / . |
Operating Temperature | 0 to 50 ( 32 to 122 ). |
Range | 0 to 250 µ g/m^3 |
Type | Particle Counter |
weight | 385 g/0.85 LB. |
Dimensions | 164 x 93 x 72 mm ( 6.5 x 3.7 x 2.8 inch ). |
Power Supply | DC 1.5V, AA ( UM-3 ) Battery X 6 PCs (Alkaline or heavy-duty battery). AC to DC 9V power adapter. |