Lutron DW-6095 Digital 3 Phase Power & Harmonics Analyzer

Lutron DW-6095 Digital 3 Phase Power & Harmonics Analyzer price in Paksitan
Inquiry
Lutron DW-6095 Digital 3 Phase Power & Harmonics Analyzer
  • Stock Availability: Inquiry
  • Model: LUTN-69
Product Views: 4926
Rs. 0/-

OVERVIEW:

Power 3 phase & harmonic analyser with transient recording - DW6095  Power quality check, power parameters, phase diagram, harmonics and transientsAC parameters, Power Factor, Phase, Harmonics,Crest Factor, Active, Apparent, Reactive PowerPeak AC voltage and currentIEC 1010 CATIII 600Vincludes 3 x 1200 amp current clamps - optional 3000amp flexible styleReal time logger 2 seconds to 7200 seconds - to SD cardTransients recorded  such as dip, swell and outage with programmable threshhold [not waveform]Display waveform, harmonics, Total harmonic distortion, phase diagramexport recorded data direct via SD card to EXCEL software for analysis3 Phase Power Analyser Lutron DW-6095 brings basic power analysis, and fault finding within the grasp of most technicians. For a modest price the user gets a complete, ready to use kit for measuring all power parameters on industrial installations to 1200amps, with extension using clamp CP3000  to 3000 amps.Whilst it is not as powerful, fast or sophisticated as some of the market leaders, the tool brings it functions to the user at 20% of the existing prices.Using the DW-6095 you can determine the peak power requirements, correct power factor problems, balance phases and identify supply faults such as wave form distortion, harmonics, breaks and surges.

Features:

  • 3 phase/4 wire, 3 phase/3 wire, 1 phase/2 wire, 1 phase/3 wire
  • True RMS measurement of ACA, ACV
  • Voltage (phase to phase), V (phase to ground), A (phase to ground) and Neutral(An)
  • KW/KVA/KVAR/PF (Phase)
  • KW/KVA/KVAR/PF (system)
  • KWH/KVAH/KVARH/PFH (system) & phase angle
  • Harmonic Display (1-50th order) & Analysis of THD
  • Simultaneously display of Harmonics and waw form
  • Graphic Phase Diagram with 3 Phase system parameters
  • 3 Phase voltage or current unbalanced ratio (VUR, AUR) and unbalanced factor
  • Capture transients events (Including Dip, swell and out age) with programmable threshold (%)
  • Real time data recorder with SD memory card (Built in clock & calendar)
  • Sampling time: 2 to 7200 sec.
  • Analysis for 3 phase multi-power system, 1P/2W, 1P/3W, 3P/3W, 3P/4W.
  • 3 current probes (CP-1201) are included, if change the current probes, the calibration procedures are not necessary.
  • Current probe input signal/ranges with selection :
  • Input signal (ACV) : 200 mV/300 mV/500 mV/1 V/2 V/3 V.
  • Ranges (ACA) : 20 A/200 A/2000 A/30 A/300 A/ 3000 A.
  • Meter can cooperate the universal current probes.
  • Complete set with 4 PCs Test Leads, 4 PCs Alligator clips, 3 PCs Clamp Probe (CP 1201), AC to DC 9V adapter, 2GB SD memory card and Carrying bag.
  • Phase angle
  • Harmonics display (1-50th order).
  • Simultaneous display of Harmonics and Wave form.
  • Display of Waveform with Peak Values.
  • Analysis of Total Harmonic Distortion (THD).
  • Graphic Phase diagram with 3-Phase system parameters.
  • 3 phase Voltage or Current Unbalanced Ratio (VUR, AUR) and Unbalanced Factor.
  • Calculated Unbalanced Current through Neutral Line (An)
  • Capture Transient events (including Dip, Swell and Outage) with programmable threshold (%).
  • Programmable CT ratio (1 to 600) and PT ratio (1 to 1000).
  • ACV input impedance is 10 Mega ohms.
  • Safety Standard : IEC 1010, CAT III 600V.
  • Built-in clock and Calendar, real time data record with SD memory card , sampling time set from 2 to 7200 seconds. Just slot in the SD card into the computer, it can down load the all the measured value with the time information (year, month, data, hour, minute, second) to the Excel directly, then user can make the further data analysis by themselves.
  • Powered by AA (UM-3) DC 1.5 V X 8 batteries (Alkaline type) or DC 9V adapter.
  • Computer data

Measurement :

  • V (phase-to-phase), V (phase-to-ground)
  • A (phase-to-ground)
  • KW / KVA / KVAR / PF (phase)
  • KW / KVA / KVAR / PF (system)
  • KWH / KVAH / KVARH / PFH (system)

Document:

Product Details
Product Name Lutron DW-6095 Digital 3 Phase Power & Harmonics Analyzer
Price Rs. 0/-
Display Specification
Display LCD Size : 81.4 X 61 mm ( 3.2 X 2.4 inch ) | Dot Matrix LCD (320 X 240 pixels ) with back light.
Summary
Data hold Freeze the display reading.
Overload protection ACV : 720 ACV rms | ACA : 1300 ACA with clamp probe
Safety Standard IEC1010 CAT III 600 V.
Voltage range 10 ACV to 600 ACV, auto range
Sampling Time Approx. 1 second
Weight Meter : 948g ( includes batteries ) | Clamp ( includded cable ) : 467g
Circuit Custom one-chip of microprocessor LSI Circuit.
HARDWARE FEATURES
Impedance ACV Input ; 10 Mega ohms.
Power Consumption Meter : 500 DCmA. | Clamp : 34 DCmA.
TECHNICAL SPECIFICATION
Operating Humidity Less than 80% R.H..
General Specification
Clamp Frequency Response : 40 Hz to 1 KHz.
Data Record SD Card Record.
Operating Temperature 0 to 50 ( 32 to 122 ).
Over Indicator LCD display show " OL ". | The data save into the SD card will show" 9999 " or " 999 " ( overleap the decimal point )
Power ON/OFF : Manual OFF by push button
Tested Frequency Spec . 45 to 65 Hz.
Wire connections 1P/2W, 1P/3W, 3P/3W, 3P/4W.
Power Supply DC 1.5V, AA ( UM-3 ) Battery X 8 PCs (Alkaline or heavy-duty battery). | AC to DC 9V power adapter.
Dimension Meter : 225 X 125 X 64 mm ( 8.86 X 4.92 X 2.52 inch ) | Clamp : 210 X 64 X 33mm ( 8.3 X 2.5 X 1.3 inch )