Hanna HI-903-02 Karl Fischer Volumetric Titrator for Moisture Determination

Hanna HI-903-02 Karl Fischer Volumetric Titrator for Moisture Determination price in Paksitan
Inquiry
Hanna HI-903-02 Karl Fischer Volumetric Titrator for Moisture Determination
  • Stock Availability: Inquiry
  • Model: HANS-35
Product Views: 3412
Rs. 1,000,000/-

OVERVIEW:

The HI903 Karl Fischer Volumetric Titrator is an automatic titrator that complements our wide range of products dedicated to efficient and accurate laboratory analysis. The HI903 analyzes for water content ranging from 100 ppm to 100%.
This powerful titrator automatically dispenses the titrant, detects the endpoint, and performs all necessary calculations and graphing.

Burettes and Dosing System:


Precision Dosing Pump:

Our unmatched 40,000 step piston-driven pump is capable of delivering as little as 0.125 µL of titrant accurately and precisely.

Chemically Resistant Tubing & Syringe:

Aspiration and dispensing tubes are constructed of durable, chemically resistant PTFE and feature a light-blocking polyurethane outer sleeve to protect light-sensitive reagents.

Anti-Diffusion Dispensing Tip:

A specially designed glass dispensing tip delivers titrant precisely into high turbulence mixing zones, ensuring a rapid reaction. Its angular construction helps prevent titrant from diffusing into the sample solvent.

Titration and Solvent System:


Efficient Sample Handling:

The HI903 features a quick-remove sample port with a replaceable rubber septum allowing for fast and easy sample introduction to the titration vessel. An integrated magnetic stirrer ensures homogeneity for an accurate and speedy reaction.

Chemically Resistant Titration Vessel:

The glass and PTFE titration cell and fittings are designed to withstand the harsh solvents and reagents involved in Karl Fischer reactions.

Sealed Solvent System:

The titration vessel is completely sealed to minimize exposure to ambient humidity, keep the system dry, and reduce titrant consumption while saving time between titrations. The solvent may be exchanged in a matter of seconds without opening the titration vessel.

Visually Recognizable Desiccant:

A rechargeable, color-indicating, silica gel desiccant prevents the ingress of ambient humidity into the sealed system while maintaining full titrator functionality. The desiccant color change allows a user to recognize when its adsorption capacity has depleted and is ready for replacement or recharging.

Titration Capabilities:


Dynamic Titrant Dosing:

The dynamic dosing feature allows for timely and accurate titration results by relating the titrant volume dosed to the mV response from the titration reaction. This provides for larger doses near the beginning of titration and smaller, more precise doses near the titration endpoint.

Drift Rate Compensation:

The HI903 automatically adjusts the titration calculation to account for the effects of any ambient humidity entering the titration cell. This provides a more accurate result by correcting for water not present in the actual sample.

Titration Results Averaging:

Successive results from a titration method may be averaged with a recording of the standard deviation.

Titrant Recordkeeping:

The HI903’s titrant database can store information for up to 20 titrants. The database may be programmed to remind a user when to standardize their titrant, reducing error in analysis.

Selectable Endpoint Criteria:

The HI903 employs a dual platinum pin electrode for voltammetric endpoint determination. Users may choose termination criteria based on mV stability times or drift rates.

Multistage Cell Preparation:

A pre-titration stage eliminates residual water present in the solvent and the cell, providing a reliable baseline start to analysis. Standby mode then keeps the solvent dry between titrations and when the titrator is not in use.

Interface and Display:


Interactive Color Display:

A large, color LCD screen clearly shows the chosen titration method along with results, units, dosing size, titration volume, drift rate, and mV value.

Detailed Titration Graphs:

A real-time titration curve can be displayed during each titration; this feature is useful when new methods are tested or when a procedure requires optimization.

Simple & Quick Navigation:

Virtual key selections present on the display allow for simple and quick navigation between screens and menus without getting lost in a nest of information.

Data and Storage:


Customizable Titration Reports:

Each titration report is fully customizable so users can ensure they are storing and filing the appropriate data required for their application and procedures.

Flexible GLP Management:

All necessary GLP (Good Laboratory Practice) information can be recorded with each sample including sample identification, company and operator name, date, time, and electrode ID codes.

Effortless Data Transfer:

Data can easily be transferred to a USB flash drive or PC with the Hanna HI900PC application software. The USB port allows for the transfer of titration methods, titration reports, and software upgrades via a USB flash drive.

Methods of Analysis:


Customizable Methods:

The HI903 can store up to 100 user-defined or standard titration methods. Each method may be customized and optimized for performance based on application and user requirements.

Titration Method Support:

Onsite installation, training, and customization are available from one of our Applications or Service experts. Hanna offers continued support via phone or webinar for any questions you might have along the way.

Adaptable Standard Methods:

Our technical experts can program and customize standard methods developed by such affiliations as ISO, ASTM, AOAC, AOCS, EPA, and more directly onto your titrator. Ask our Sales Consultants which standard methods are possible with our HI903 Karl Fischer system.

Connectivity and Functionality:


Configurable Balance Interface:

Sample size may be automatically entered from any laboratory analytical balance with an RS232 serial output saving time and labor.

Multiple Peripherals:

Users can print reports directly from the titrator using a standard parallel printer. An external monitor and keyboard may be attached for added versatility, as well as an analytical balance for automatic sample mass entry for titrations.

Versatile Data Management:

HI900 Series titration systems can be easily incorporated into any existing GLP data management program.
Easily record all necessary GLP information with every sample, such as sample identification, company, and operator name, date, time, electrode ID codes, and calibration information

  • Data can be transferred to a PC using Hanna HI900PC software
  • The USB port allows for the easy transfer of methods, reports, and software upgrades via a USB flash drive
  • Users can print reports of analyses directly from the titrator using a standard parallel printer
  • An external monitor and keyboard can be attached for added versatility

Document:

Product Details
Product Name Hanna HI-903-02 Karl Fischer Volumetric Titrator for Moisture Determination
Price Rs. 1000,000/-
TECHNICAL SPECIFICATION
Electrode Type: HI76320 dual platinum pin, polarization electrode | Connection: BNC | Polarization Current: 1, 2, 5, 10, 15, 20, 30 or 40 μA | Voltage Range: 2 mV to 1000 mV | Voltage Resolution: 0.1 mV | Accuracy (@25°C/77°F): ±0.1 %
Titration Range: 100 ppm to 100% | Resolution : 1 ppm to 0.0001% | Result Units: %, ppm, mg/g, μg/g, mg, μg, mg/mL, μg/mL, mg/pc, μg/pc | Sample Type: liquid or solid
General Specification
Clip Lock Burette System Dosing Pump Resolution: 1/40000 of the burette volume (0.125 μL per dose) with 5 mL burette | Dosing Pump Accuracy: ±0.1% of full burette volume | Syringe: 5 mL precision ground glass with PTFE plunger | Valve: motor-driven 3-way, PTFE liquid contact material | Tubing : PTFE with light block and thermal jacketing | Dispensing Tip: glass, fixed position, anti-diffusing | Titration Vessel: conical with operation volume between 50-150 mL| Solvent Handling System: sealed system, integrated diaphragm air pump
Determination Pre-Titration Conditioning: automatic | Background Drift Correction: automatic or user-selectable value | Endpoint Criteria: fixed mV persistence, relative drift stop, or absolute drift stop | Dosing: dynamic with optional pre-dispensing rate Result Statistic: mean, standard deviation
Stirrer Type: magnetic, optically regulated, digital stirrer | Speed: 200-2000 rpm | Resolution: 100 rpm
Weight approximately 10 kg (22 lbs.)