Schneider Power Factor Controller VPL12N
Rs. 135,000/-
Available Options
Schneider Power Factor Controller VPL12N price in Pakistan is
Rs. 135,000/-
. W11stop.com has wide range of Industrial Automation & Circuit Protection with cash on delivery service in Karachi, Lahore, Multan, Peshawar and many other cities.
FEATURES:
- Varplus logic 12 step
- Power factor controller with automatic initialization & automatic detection
- Metering type:
- voltage U21, U32, U13, V1, V2, V3, on load
- Apparent power S, S1, S2, S3, on load
- Reactive power Q, Q1, Q2, Q3, on load
- Active power P, P1, P2, P3, on load
- Phase current 11, 12, 13 RMS on load
- Temperature maximum
- Power factor average over lifetime
- Total current harmonic distribution THD (I)
- Power factor and displacement PF(Signed, Four Quardrant)
Document:
Schneider Power Factor Controller - VPL12N
Product Details | |
Product Name | Schneider Power Factor Controller - VPL12N |
Price | Rs. 78,000/- |
Computers Specs | |
Color | Front : dark grey (RAL 7016) |
Display Specification | |
Display | Backlit LCD |
Display size | 56 x 25 mm |
Name | VarPlus Logic |
Summary | |
Ambient Air Temperature for Operation | -20...60 °C |
Function | Automatic initialisation Automatic detection Manual programming Advanced programming (expert) Any step sequence |
Height | 144 mm |
Weight | 0.6 kg |
Depth | 58 mm |
Output Type | Control relay : 0.2 A 110 V DC Control relay : 1 A 48 V DC Control relay : 2 A 400 V AC 50/60 Hz Control relay : 1 A 24 V DC Control relay : 5 A 250 V AC 50/60 Hz Control relay : 5 A 120 V AC 50/60 Hz Fan : 5 A 250 V AC 50/60 Hz Fan : 1 A 48 V DC Alarm relay : 5 A 250 V AC 50/60 Hz Alarm relay : 1 A 48 V DC |
HARDWARE FEATURES | |
Input Type | Current input CT...X/5 A and X/1 A Insensitive to CT polarity Insensitive to phase rotation polarity Phase to neutral Phase to phase |
IP degree of protection | Rear face : IP20 Front face : IP41 |
Mounting Mode | Flush-mounted |
Supply Voltage | 90...550 V AC |
Mounting | In cabinet |
Type | |
product or component type | Power factor controller |
UC100 | |
Standards | EN 61010-1 IEC 61000-6-2 IEC 61000-6-4 UL 61010-1 IEC 61326-1 |
General Specification | |
Connection | Communication protocol: Modbus interface: RS485 ` |
Contacts | 12 |
Type For | Metering Power factor and displacement PF (signed, four quadrant) Total current harmonic distortion THD (I) Power factor average over lifetime Temperature maximum Phase current I1, I2, I3 RMS on load Active power P, P1, P2, P3 on load Reactive power Q, Q1, Q2, Q3 on load Apparent power S, S1, S2, S3 on load Voltage U21, U32, U13, V1, V2, V3 on load |
Width | 144 mm |
Alarm | Step power loss (< 75 %) / Action: message and alarm contact + step blocked Step faulty / Action: message and alarm contact + step blocked High current (> 6 A CT) / Action: message and alarm contact Hunting (unstable regulation) / Action: message and alarm contact + step blocked Low current (< 15 mA CT) / Action: message and alarm contact Capacitor current overload (Irms/I1) (> 130 % I1) / Action: message and alarm contact + step switched off Overtemperature (50 °C) / Action: message and alarm contact + step switched off Overtemperature (30 °C) / Action: fan switch Overvoltage (+/- 10 %) / Action: message and alarm contact + control stopped Total harmonic distortion (> 7 %) / Action: message and alarm contact + step switched off Overcompensation / Action: message and alarm contact |
OTHERS | |
Certifications | CE EAC NRTL CNRTL |