Menu
Your Cart
"Due to currency devaluation, the prices are subject to change without prior notice. Please confirm the price before placing the order."

Nokian N6 Power Factor Controller

OVERVIEW:

Power Factor Controller:

  • Digital 6 steps with Alarms.
  • With Built-in Power Analyzer.
  • With Continuous Digital Power Factor & Capacitor Steps Display.
  • With Automatic serach of C/K values.
  • Automatic CT polarity adjustment and Automatic Phase Rotation polarity adjustment.

Measurement And Display:

  • Power Factor.
  • Connected Steps.
  • Switching Counter and duty cycles.
  • Current.
  • Voltage.
  • KVA.
  • KW.
  • KVAR.
  • Panel Temperature (built-in temperature probe).
  • Total Voltage Harmonic Distortion : THD (U).
  • Alarm voltage.

Features:

  • Backlighted alphanumeric LCD with graphical 160 symbols, for continuous display of Power Factor and Capacitor steps.
  • Power Factor display 0.00 ind. ... 1.00 ... 0.00 cap.
  • LCD display for alarm and ind/cap.
  • CT ratio settings and display : 25/5 ... 6000/5.
  • Target PF setting and display : 0.85 ind ... 1.00 ... 0.90 cap.
  • Setting and display of step sizes : 10 ... 1000 KVAR.
  • Setting and display of input volatge : 80 ... 460V.
  • Automatic search of C/K values. C/K setting and display 0.00 ... 1.99.
  • Easy to use menu-driven user interface.
  • Automatic Polarity adjustment of CT connections.
  • Automatic Polarity adjustment of Phase rotation.
  • Separate alarm relay with potential free terminal.
  • Following Alarms can be selected (enable/disable and status) low power factor, hunting, abnormal Cos, undervoltage, overcapactive, wrong frequency, overcurrent, overvoltage, overtemperature (for fan and system) and voltage harmonic distortion (THD).
  • All steps are released at voltage dropout.
  • Number of steps setting and display 1 ... 12.
  • Manual stepping setting and display.
  • Fixed stepping setting and display.
  • Plug in connection at rear side.
  • State of art microprocessor technology.
  • Suitable for LV and HV networks.
  • Allows Self-Configuration.

Performance:

  • intelligent stepping algorithm for optimum step utilization and fast response
  • all traditional stepping sequences also available

Simplified Installation And Set-Up:

  • quick and simple mounting and wiring
  • insensitive to current transformer polarity and phase rotation polarity
  • a special menu allows controller self-configuration

Monitoring And Protection:

Alarms:

  • should a disturbance occur on the network or in the capacitor bank, alarms are indicated on the screen and alarm contact closure is initiated
  • The alarm message is maintained on the screen once
  • The fault clears and until it is manually reset
  • Last five alarms are stored in alarm log

Product Details
Product Name Nokian N6 Power Factor Controller
Price Rs. 200,000/-
Summary
Ambient Temperature 0 to 60 degree C.
Size 144 x 144 x 60mm, Protection Class : IP41.
HARDWARE FEATURES
Supply Voltage Measurement And Supply Voltage : 230V(+,-)15%, OR 400V(+,-)15%, OR 110V(+,-)15%.
General Specification
Alarm Relay N.O., Contact Ratings : 2.0A/400VAC.
Connection with or without Neutral Line. i.e. : LN=Phase to Neutral or LL=Phase to Phase.
Frequency 50 or 60Hz (+,-) 2Hz, automatic selection.
Model N6.
Operation Sequence user selectable from menu. normal : 1:2: 4: 4; stack 1:1:1:1: circulating A : 1: 1: 1: 1; Circulating B : 1: 2: 2: 2: .
Output Relay N.O., Contact Ratings : 2.0A/400VAC.
Step Reconnection Delay Adjustable from 10... 600 secs.
Type Power Factor Controller with built-in Power Analyzer.

Write a review

Note: HTML is not translated!
Bad Good